Nitrogen and zero generator (H2+Air)

Home > Products > Gas Generator > Nitrogen and zero generator (H2+Air) >

Hydrogen gas generator

The FID STATION PLUS hydrogen and air generator uses the latest proton exchange membrane (PEM) technology to prod...

Model: FID FLAT-NM Plus series

Order NO.:

1071

Specific parameters will be adjusted according to product upgrades, without notice.

Quotation Request

PRODUCT OVERVIEW

Description

The FID STATION PLUS hydrogen and air generator uses the latest proton exchange membrane (PEM) technology to produce pure hydrogen. The hydrogen is ideal for use in gas chromatographic detectors such as FID, NPD, and TCD, and as a reagent gas for ELCD and HALL.

The horizontal format is designed to sit under and support the weight of your GC, optimizing bench space.  At only 17 cm high, the generator will still allow easy access to the injectors of any GC on the market. De-ionized water is automatically loaded from smart internal system tanks with a 3 litre capacity, providing up to 3000 litres of H2 before a refill is required.  The only recommended maintenance is replacement of the internal deionizing cartridge, which has been greatly simplified.

FID Station PLUS models produce an H2 flow of up to  600cc/min with a purity of 6.0, or up to 1000cc/min with a purity of 7.0. The optional zero air generator provides 1.8 l/min or 5 l/min of zero air with HC content around 0.5ppm.

FID Station Plus FEATURES

USER-FRIENDLY CONTROLS
Full microprocessor control
LCD touch screen interface or push buttons: real time outlet pressure, water quality, auto diagnostics, leak detectors, water level, and quality sensors

POWERFUL WATER PUMP
Optimized powerful water pump for PEM cell

CASCADING
The ability to "cascade", or install several hydrogen generators in parallel, provides:
• Higher flow rates - up to 10 lpm
• Automatic flow compensation in the event of unplanned downtime
• Continuous operation for critical applications

FID Station Plus BENEFITS

SAVINGS
Hydrogen gas generators eliminate the need for expensive installation of gas pipelines from the cylinder storerooms to the labs, as well as the need to repeatedly change the bottles. The dual configuration H2 or H2 + Air, available in a single instrument, saves space and money.

IMPROVED CHROMATOGRAPHIC RESULTS
Hydrogen as a carrier gas is faster and more sensitive than the more expensive helium, providing run time savings of 25% to 35% without a decline in resolution.

EASY USE AND MAINTAINENCE
The unit features remote software control via RS232, USB, or intranet. With automatic cold dryer regeneration, there are no caustic solutions used. Maintenance is simplified by our deionizer bag access system, which allows changing out the deionizer bag without tools, without even turning off the instrument.

IMPROVED SAFETY
The very small internal volume (less than 50 ml) allows safe use of gas generators where the use of cylinders is risky or prohibited. The application of tested safety technologies stops the unit in the event of leaks or malfunction. An optional hydrogen sensor is available for monitoring the oven-LEL of the GC. The VICI DBS Plus series also includes additional security features like a shock sensor to prompt shutdown in the event of an earthquake.

INCREASED PRODUCTIVITY
Round the clock continuous operation maximizes lab productivity, eliminating dead time for gas bottle changeover and maintenance of the drying system.

OPERATING PRINCIPLE
Hydrogen is produced by forcing distilled or deionized water through a sophisticated Swiss-made fuel cell. Electrolytic dissociation separates the water into its two main components: hydrogen ready for analytical use, and oxygen that is released into the air. No acid no alkaline solutions are used in the hydrogen generation cycle. The patented automatic drying system ensures the maximum grade of hydrogen purity.  

Specifications
FID FLAT-NM Plus series
for all GC Detectors and Carrier Gas Applications

Models(H2)

FID FLAT-NM

100 Plus

FID FLAT-NM

100 Plus

FID FLAT-NM

600 Plus

FID FLAT-NM

1000 Plus

Flow rate (ml/min)

100

300

600

1000

Weight (kg)

approximated 35

Purity

99.99996%

Display

Operating parameters, system status, alarms and touch screen

LED Indicators

Power on/off, system ready, errors

Membrane

Polymer Electrolyte Membrane(PEM)

Dryer

Exclusive cold dual dynamic regeneration system

Max Outlet Pressure

11 bar (160 psig)

Internal Volume

<50 ml at max pressure

Water quality

Deionized or demineralized (<2μs)

Internal water tank system

7L autore_ll included

Cascading

The exclusive cascading option allows up to 32 units to be connected in series

Connections

1/8 swagelock

Power

110-120 60 Hz / 220-240 50 Hz

Dimensions(mm)

690W x 150H x 680D

Tested weight support (kg)

80

Connection

USB mod A

Certi_cations

CE, CSA, FCC

Options

RS232/RS485 and USB, external contacts, PC software,Manage & Control, Intranet

skype
  • CONTACT

  • WIGGENS GmbH
  • Gässlesweg 22-24, 75334 Straubenhardt, Germany
  • Tel.: +49 7248 4529088
  • E-mail: info@wiggens.com

  • WIGGENS CHINA
  • Room 426, Hall A, Office Building M8, No. 1 Jiuxianqiao East Road, Chaoyang District, Beijing
  • Tel.: +86 400-809-2068
  • info@wiggens.com
  • www.wiggens.com

About Contact Statement Privacy Policy