Max.temperature:200℃;Max.pressure:25bar
Model: NR-5L
Order NO.: NR-5L
1884
Specific parameters will be adjusted according to product upgrades, without notice.
The NR reactors enable experiments with 5L to 200L and negative pressure. In comparison to the other series of reactors, no loss of flexibility or safety has to be made. Easy handling and highest safety and maximal flexibility and individuality.
Each of low pressure reactors can be equipped with a bottom drain valve. NR-5L reactors without a bottom drain valve can be provided with a PTFE insert. However, reactors with a bottom drain valve cannot be equipped with PTFE inserts. NR-5L to NR-200L reactors with a bottom drain valve have three different configurations:
● Basic configration for M1
● Basic configuration with distillation unit for M2
● Basic configuration with short-path distillation unit for M3
Standard armatures of the Low-pressure Reactor are a rupture disc, a dip tube, a valve and a tool for opening and closing the reactor. In total, NR-5L to NR-200L have eight ports, e.g. for pressure monitoring. The ports can be used according to customer needs. The number of free ports can be enlarged when using T-connections.
Features
● 5L~200L / 25 bar / 200℃
● With or without jacket, with bottom outlet
● Quick closure chain design
● O-seal ring made of Viton, Other materials are optional
● Heating by electrical or thermostated mantle
● Stirring by overhead stirrer
Technical specification
NR-5L | |
General information | |
Material | Stainless Steel 316L |
Max.temperature | 200℃ |
Max.pressure | 25bar |
Reactor vessel | |
Volume (approx.) | 6460 ml |
Inner diameter | Ø 219 mm |
Inner height | 234 mm |
Thickness | 6 mm |
Bottom drain valve | With |
Configration | |
Standard configration | Rupture disc, dip tube, valve, tool. Basic configration for M1, basic configuration with distillation unit for M2 Basic configuration with short-path distillation unit for M3 |
Pressure measurement | Analog and/or digital |
Port (total) | 8 |
Type of connection | 8 mm tube connection |
Heating systems (optional) | |
Electrical (Heating jacket) | Yes |
Via fluid (Double jacket) | Yes |
Stirring (Magnetic drive) | |
RV-GL | Yes |
RV-400 | No |